Product principle
The intelligent lightning rod is a kind of advance discharge lightning rod. It has a built-in permanent pulse core monitoring module and a lightning strike counting module, which can be remotely transmitted to the monitoring center through the built-in communication module. C terminal and mobile terminal, conduct real-time online supervision, and accurately grasp the working status of the lightning rod and lightning strike data records. The energy of the lightning rod comes from the internal solar power supply system without the need to obtain energy from an external power supply or atmospheric electric field. Combined with an accurate detection and triggering device, it has become the most advanced Advanced early discharge lightning rod.
Product Efficacy
Advance pulse discharge: The intelligent online monitoring lightning rod has a super strong pulse discharge core, and its advance discharge capability has reached unprecedented levels. It comes with a high-performance solar panel for core work and online operation. Monitoring provides permanent motivation.
Lightning strike information recording: Randomly record the time of lightning strike, lightning strike location (location map alarm), record the number of lightning strikes by lightning rods, record the peak value, polarity and energy generated by lightning strikes, and transmit it to the cloud via /network for permanent storage. It is convenient for future reference and provides sufficient scientific basis for lightning research.
Lightning rod core monitoring: Real-time monitoring of the working status of the core components of the lightning rod, including the operation of the circuit board, the failure of resistors, capacitor discharge tubes, inductors and other components, etc. If one day it is found that the work is abnormal or stops working, the lightning rod The built-in communication module will immediately push relevant abnormal parameters to the monitoring center or mobile phone terminal, and issue an alarm to relevant staff for repair as soon as possible.
Lightning rod ground monitoring: The lightning rod has a built-in ground failure alarm module, which records the resistance value between the lightning rod and the ground grid at any time. When the connection resistance between the lightning rod and the ground grid exceeds the set critical value, the system determines that there is a ground failure. , and sends the relevant parameters of the failure to the monitoring center and maintenance personnel's mobile terminals through the lightning rod communication module, prompting the staff to perform timely maintenance and restoration.
Protection radius
The protection radius of the smart lightning rod is related to the height and the selected protection level:
When > R=&r()+△
(+△)c discharges in advance When the time reaches
& above
c Solar power permanently
When installed, see the protection radius table c Remote signaling transmission, cloud storage
c=
Higher than the level of the protected object
c= Category 1 lightning protection buildings
c= & Class II Lightning Protection Buildings
c= The third type of lightning protection building
Core self-detection function
Pre-discharge lightning rods have built-in high voltage Pulser or other circuit board components, and once the pulser fails, the lightning rod will not only lose its early discharge function, but also lose its circuit conduction function. When lightning strikes, serious losses will be caused. Traditional pre-discharge lightning rods can only be detected manually at regular intervals, or even cannot be detected, and the working status of the lightning rod cannot be guaranteed. Intelligent online monitoring lightning rods have a built-in self-detection system and permanently monitor the working status of the lightning rod. Once an abnormal working condition is found or If it cannot work, the built-in intelligent communication module of the lightning rod will immediately transmit relevant failure indication information to the lightning protection monitoring center or other terminals, and notify relevant maintenance personnel to perform maintenance or replacement to avoid unnecessary disasters caused by lightning rod failure. ,